junos ccc layer 2 switching on a single PE
[An image from the original post was not archived.]
Similar to L2VPN, circuit cross connect is a good way to quickly build up ethernet switching on a single MPLS PE. It’s very easy to build CCC connections. Here an an example:
fe-0/3/1 {
vlan-tagging;
encapsulation vlan-ccc;
unit 0 {
encapsulation vlan-ccc;
vlan-id 800;
}
}
fe-0/3/2 {
vlan-tagging;
encapsulation vlan-ccc;
unit 0 {
encapsulation vlan-ccc;
vlan-id 800;
}
}
connections {
interface-switch router1-to-router2 {
interface fe-0/3/1.0;
interface fe-0/3/2.0;
}
}
ps@presidio-r10# run show connections
CCC and TCC connections [Link Monitoring On]
Legend for status (St) Legend for connection types
UN -- uninitialized if-sw: interface switching
NP -- not present rmt-if: remote interface switching
WE -- wrong encapsulation lsp-sw: LSP switching
DS -- disabled tx-p2mp-sw: transmit P2MP switching
Dn -- down rx-p2mp-sw: receive P2MP switching
-> -- only outbound conn is up
<- -- only inbound conn is up Legend for circuit types
Up -- operational intf -- interface
RmtDn -- remote CCC down tlsp -- transmit LSP
Restart -- restarting rlsp -- receive LSP
Connection/Circuit Type St Time last up # Up trans
router1-to-router2 if-sw Up Aug 12 09:29:55 1
fe-0/3/1.0 intf Up
fe-0/3/2.0 intf Up
Originally published on truman.net. See the archived copy.